Plug the main fan on an air cooler into CPU_FAN. Use CPU_OPT for the cooler’s second fan if your motherboard has that header and the cooler has two separate fan leads. Plug case intake and exhaust fans into SYS_FAN or CHA_FAN. If you’re wiring an all-in-one liquid cooler, start with its manual. Depending on the cooler, the cable that goes to CPU_FAN could be a radiator fan lead, a combined control cable, or a pump speed signal.
The headers can look alike, even when they sit next to one another. The differences you’ll notice are which temperature drives the fan, whether you can set a separate speed curve, and which header your motherboard watches during startup.
CPU_FAN, CPU_OPT, SYS_FAN and AIO_PUMP at a glance
| Header | Typical connection | Speed control | What to check |
|---|---|---|---|
| CPU_FAN | Main cooler fan or the lead specified by an AIO manual | Usually a CPU temperature-based curve | Startup RPM monitoring and the fan’s PWM or DC mode |
| CPU_OPT | Second fan on the CPU cooler | Shares CPU_FAN control on some boards | Whether it has its own curve and whether the manual permits pump use |
| SYS_FAN or CHA_FAN | Case intake or exhaust fan | System or chassis fan curve with temperature sources that vary by board | Which sensor the header can use and what current it can supply |
| AIO_PUMP or PUMP_FAN | Compatible liquid cooler pump lead | May default to full speed or offer pump-specific controls | The pump’s power, speed control and monitoring requirements |
What each fan header does
CPU_FAN is the main cooler connection
For a single-fan tower cooler, this is where the fan cable goes. The motherboard can use CPU temperature to tell the fan when to speed up, then read the fan’s tachometer signal to see how fast it’s actually turning. A board that checks CPU_FAN at startup can show a warning if that socket receives no RPM signal. So you could have a visibly spinning cooler fan on a neighboring header and still get an error. ASUS CPU fan error guidance
CPU_OPT is an optional second CPU cooling connection
On a dual-fan tower, CPU_OPT gives the second fan its own place to plug in. The ASUS TUF Gaming B650-Plus WiFi manual lists CPU_FAN and CPU_OPT in the same control group. If you plug one fan into each, the board commands them together. Fans can still report different speeds at the same setting, especially if they’re different models. Read your board’s fan header table before relying on a particular control arrangement. ASUS motherboard manual
SYS_FAN and CHA_FAN serve the case
These are two names manufacturers use for case fan headers. If there’s a front intake pair and a rear exhaust fan, look for numbered headers within cable reach, then match those numbers to the fan controls in firmware. The motherboard may let you pick a temperature source for a case header. For a GPU-heavy build, choose a sensor that reflects heat inside the case if your board offers a suitable one. Our case fan installation guide covers connector routing and airflow direction.
Single-fan air cooler Main cooler fan → CPU_FAN Dual-fan air cooler Main cooler fan → CPU_FAN Second cooler fan → CPU_OPT Case airflow Intake / exhaust → SYS_FAN or CHA_FAN
How to find the right header on your motherboard
Switch off the PC and disconnect its power before moving plugs. Start at the top edge of the board near the CPU socket. That’s where you’ll find CPU_FAN and CPU_OPT on boards such as the ASUS TUF Gaming B650-Plus WiFi. Look for the small label printed by the pins and orient yourself using the board diagram in the manual. A cooler can hide a label once it’s mounted, so mark the right cable or work out its route while the header is still visible.
Look up the connector names if you see a suffix or a combined label. The Gigabyte B650 AORUS Elite AX manual, for example, calls CPU_OPT a CPU fan or water cooling pump header and lists a separate SYS_FAN4_PUMP header. The connector on another board could have a different assignment or current rating. Match the fan plug’s guide grooves to the tab on the header and seat it squarely without forcing it. Gigabyte motherboard manual
Can you use CPU_OPT for a case fan?
Yes, if the motherboard supports that fan’s connector, control mode and current draw. A separate curve for case airflow. That’s the practical advantage of choosing SYS_FAN first. If CPU_OPT shares the CPU curve, a short CPU temperature spike can make the attached case fan ramp up with the cooler. That may be fine for a rear exhaust directly behind a tower cooler. A front intake feeding the graphics card could benefit more from a different curve or a steadier minimum speed.
Look at the curve and the RPM readout separately when you tune the fans. The curve sets the control signal at a given temperature. RPM is what the fan is doing in response. For example, two cooler fans on the same curve can react together when the CPU heats up, while a case fan on its own curve can keep a steady intake at the same moment. If your front fans are loud during light work, check which temperature they follow before changing the CPU cooler curve.
What if you run out of fan headers?
When the issue is a missing CPU_OPT, a splitter can put two compatible PWM cooler fans on CPU_FAN. One cable, two fans. The Noctua NA-SYC1 is one example, and your cooler may already include a splitter. Both fans get the same control signal, and one branch returns RPM. Put the main cooler fan on the branch that carries the speed signal. Add the fans’ maximum current figures and check that the total stays below the board’s limit. On the ASUS example above, two fans rated at 0.20 A each would total 0.40 A on a 1 A header. Noctua splitter specifications and combined current guidance
For several case fans, a hub that takes power from the power supply can ease the load on a motherboard header. Check how the hub receives its speed command and which output passes a tach signal back. If a front intake group should run at one speed while the rear exhaust runs at another, plan for two independently controlled outputs. A simple splitter or a hub with one shared control input gives that whole group one command.
Where does an AIO pump go?
Read both manuals before deciding. For a cooler with separate pump and radiator fan leads, the manual may direct the pump lead to AIO_PUMP or PUMP_FAN and have the radiator fans report speed to CPU_FAN. Check the prescribed mode and speed for the pump header. The ASUS board above, for example, lists full speed as the default for AIO_PUMP.
Some coolers use a different wiring scheme. The ARCTIC Liquid Freezer III 240 has an all-in-one PWM cable that controls the pump, VRM fan and radiator fans together and reports pump speed. It also includes a cable for individual control that needs three 4-pin headers. The Corsair iCUE LINK RGB AIO family routes a tach lead from the System Hub to CPU_FAN and powers the hub separately. Two coolers can put very different signals on CPU_FAN while both following their instructions. ARCTIC installation manual and Corsair installation manual
If you’re shopping for a liquid cooler and are counting connectors before you buy, check whether the fans use a single lead, individual leads or a hub. Radiator size affects the physical fit, too. Our two-fan vs three-fan AIO comparison walks through the size trade-offs.
Which header should you use?
- One tower cooler fan. Use CPU_FAN and leave CPU_OPT open.
- Two tower cooler fans. Put the main fan on CPU_FAN and the second on CPU_OPT. On boards without CPU_OPT, use the cooler’s splitter or a compatible one after checking the current limit.
- Case intake or exhaust. Start with SYS_FAN or CHA_FAN so you can tune case airflow separately when the board allows it.
- Liquid cooler. Follow the cooler’s cable map, then check which RPM can be read in firmware and which fan or pump each curve actually controls.
On first boot, check that the connected fans spin and that the expected RPM readings appear in the firmware monitor. If you’ve used a splitter, watch both fans during that first check because the firmware displays only the monitored branch. If CPU temperature climbs quickly or the cooling hardware shows no sign of running, shut down and check the connections. If the fan is turning but you get a warning, follow our CPU fan error walkthrough to check the header and low-speed threshold.
Frequently asked questions
Can a 3-pin fan plug into a 4-pin motherboard header?
It can on a compatible keyed fan header. If you want the board to vary the speed, look for DC or voltage control in that header’s settings. A 4-pin PWM fan instead receives its speed command on the fourth pin. Gigabyte’s B650 AORUS Elite AX manual shows both voltage and PWM speed control pins on the fan headers. Available control options depend on the board and header.
Does the fan’s RGB cable go into the same header?
A fan with separate motor and lighting leads typically has two connections. Route the motor lead to the fan header, and route the lighting lead to the compatible RGB or addressable RGB connector or controller specified by the fan maker. Check the lighting voltage and pin layout in both manuals before you connect it. The Gigabyte board above, for example, has separate 5 V addressable and 12 V RGB headers.

Write Your Review